What is a industrial chiller ?
May 17 , 2021
Industrial chillers are one type of chillers, and chillers can be divided into air-cooled chillers and water-cooled chillers. Water chiller is a kind of water cooling equipment, which can provide constant temperature, constant current and constant pressure cooling equipment. The principle of the chiller is to inject a certain amount of water into the internal water tank of the machine, and the wat...
Read More
-
How to clean a water chiller?
Jun 05 , 2021
How to clean a water chiller? As a fixed asset of an enterprise, the chiller is a must for enterprise personnel to maintain it and maximize its usefulness. Because the long-term operation of the chiller will cause thick scale on the surface of the condenser, which will interfere with the normal operation of the chiller. For example, to make its work efficiency low or easy to damage, etc., the nece...
Read More
-
Common failures in chiller maintenance
Jul 02 , 2021
Common failures in chiller maintenance During the maintenance of the chiller, in some environments with many dust layers, after the chiller has been used for a period of time, we will find that the chiller is noisy, and there are many dust layers on the accessories. This is a common phenomenon in the use of the chiller. At this time, the chiller is We need to serve it. First of all, the chill...
Read More
-
Requirements for adding refrigerant to industrial chiller system
Jul 05 , 2021
After the industrial chiller system has passed the vacuum test, the vacuum state in the system can be used to charge the refrigerant. 1. Refrigerant charging For newly installed systems, refrigerant can be added to the high-pressure end, and the operation method is as follows: 1) Turn on the cooling water system for the condenser, and keep the valve in the system as it was during the vacuum test 2...
Read More
-
How to size a chiller - chiller cooling capacity caculation
Jul 06 , 2021
The calculation method of chiller cooling capacity and the calculation summary of chiller selection (1) How to choose the most suitable industrial chiller and screw chiller? In fact, there is a simple selection formula: Cooling capacity = chilled water flow * 4.187 * temperature difference * coefficient 1. The flow rate of chilled water refers to the flow rate of chilled water required when the ma...
Read More
-
Chiller installation and maintenance instructions
Jul 09 , 2021
Chiller installation and maintenance instructions 1. Installation instructions 1. Machine installation, it is required to lay flat and not tilt; 2. There should be a maintenance space of about one meter on both sides of the machine; 3. Connect the cooling water inlet and outlet specifications of this machine to your cooling system; 4. The ice water pipe must be replaced with a loop to allow the ic...
Read More
-
Requirements for adding refrigerant to industrial chiller system
Jul 30 , 2021
After the industrial chiller system has passed the vacuum test, the vacuum state in the system can be used to charge the refrigerant. 1. Refrigerant charging For newly installed systems, refrigerant can be added to the high-pressure end, and the operation method is as follows: 1) Turn on the cooling water system for the condenser, and keep the valve in the system as it was during the vacuum test 2...
Read More
-
Common sense problems that should be paid attention to in the use of industrial chillers
Aug 06 , 2021
In many industries, industrial chillers are required. The industrial chiller mainly achieves the refrigeration effect through absorption cycle vapor compression or vapor compression. These liquids can flow through the heat exchanger to cool the air or equipment. When we use industrial chillers, in order to ensure safety, we should master the following precautions for safe operation of industrial c...
Read More
-
Four methods for judging the flow of chilled water in a chiller
Aug 13 , 2021
Generally speaking, when buying a chiller, you will have questions. I don't know how to judge the chilled water flow rate of the chiller? From what aspects should the chiller water flow be considered? Here is a brief talk. The detection of the return water temperature and the outlet water temperature of the chiller should be carried out in the normal state of the unit: After 30 minutes of starting...
Read More